Vnitr Lek 2004, 50(12):887-893

[The activation of haemostasis during radiofrequency catheter ablation].

P Parízek, L Haman, J Malý, M Pecka, M Hodac, J Bukac, P Stránský, R Malý, J Duda, M Pleskot
Lékarské fakulty UK a FN, Hradec Králové.

Klíčová slova: Adult; Aged; Catheter Ablation, adverse effects, ; Electrophysiologic Techniques, Cardiac; Female; Hemostasis; Humans; Male; Middle Aged; Tachycardia, Supraventricular, blood,

The aim of the study was to investigate chosen haemostasis activation markers during electrophysiologic study (EPS) with consequent radiofrequency catheter ablation (RFA). Sixty-three patients were studied prospectively. Indications for EPS and RFA were supraventricular tachycardias with the arrhythmogenic substrate located in the right atrium. Blood samples were drawn 24 hours before the procedure (T -1), at the beginning of the procedure (T0), at the end of EPS (T1), 30 minutes after completion of RFA (T2), and 24 hours after the procedure (T3). To study coagulation, fibrinolytic and platelet activation were measured concentrations of thrombin-antithrombin III (TAT), D-dimers (DD), platelet count and parameters, and circulating platelet aggregates (CPAi). During the EPS and RFA, TAT levels increased from the baseline 5.03 +/- 2.53 microg/l (T -1) to 12.90 +/- 12.83 microg/l at T0 (p < 0.001) to 36.07 +/- 15.59 microg/l at T1 (p < 0.001) and decreased to 28.85 +/- 13.14 microg/l at T2 (p < 0.001). Levels of DD increased from 0.30 +/- 0.20 mg/l at T0 to 0.44 +/- 0.25 mg/l at T1 (p < 0.001) and to 0.87 +/- 0.74 mg/l at T2 (p < 0.001). The number of platelets was significantly decreased (-13.7%) before and during the procedure (T -1 vs. T3; p < 0.001). Marked platelet activation (CPAi 0.62 +/- 0.32) was observed before the procedure opposite to the physiological values (CPAi 1.0 +/- 0.1), without changes during the procedure (CPAi at T2 0.69 +/- 0.23). Our results confirmed activation of several haemostasis parameters during EPS and RFA, and support eligibility of the antithrombotic prevention in patients indicated for EPS and RFA.

Keywords: Adult; Aged; Catheter Ablation /adverse effects/; Electrophysiologic Techniques, Cardiac; Female; Hemostasis; Humans; Male; Middle Aged; Tachycardia, Supraventricular /blood/

Zveřejněno: 1. prosinec 2004  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Parízek P, Haman L, Malý J, Pecka M, Hodac M, Bukac J, et al.. [The activation of haemostasis during radiofrequency catheter ablation]. Vnitr Lek. 2004;50(12):887-893.
Stáhnout citaci




Vnitřní lékařství

Vážená paní, pane,
upozorňujeme Vás, že webové stránky, na které hodláte vstoupit, nejsou určeny široké veřejnosti, neboť obsahují odborné informace o léčivých přípravcích, včetně reklamních sdělení, vztahující se k léčivým přípravkům. Tyto informace a sdělení jsou určena výhradně odborníkům dle §2a zákona č.40/1995 Sb., tedy osobám oprávněným léčivé přípravky předepisovat nebo vydávat (dále jen odborník).
Vezměte v potaz, že nejste-li odborník, vystavujete se riziku ohrožení svého zdraví, popřípadě i zdraví dalších osob, pokud byste získané informace nesprávně pochopil(a) či interpretoval(a), a to zejména reklamní sdělení, která mohou být součástí těchto stránek, či je využil(a) pro stanovení vlastní diagnózy nebo léčebného postupu, ať už ve vztahu k sobě osobně nebo ve vztahu k dalším osobám.

Prohlašuji:

  1. že jsem se s výše uvedeným poučením seznámil(a),
  2. že jsem odborníkem ve smyslu zákona č.40/1995 Sb. o regulaci reklamy v platném znění a jsem si vědom(a) rizik, kterým by se jiná osoba než odborník vstupem na tyto stránky vystavovala.


Ne

Ano

Pokud vaše prohlášení není pravdivé, upozorňujeme Vás,
že se vystavujete riziku ohrožení svého zdraví, popřípadě i zdraví dalších osob.