Vnitr Lek 1999, 45(12):691-695

[Evaluation of the results of percutaneous transluminal angioplasty of arterial stenosis in the transplanted kidney using area under time curves of the glomerular filtration rate and blood pressure].

J Stríbrná, O Schück, J H Peregrin, D Krajícková, J Skibová
Klinika nefrologie IKEM, Praha.

Klíčová slova: Adult; Angioplasty, Balloon; Area Under Curve; Blood Pressure; Female; Glomerular Filtration Rate; Humans; Kidney Transplantation, adverse effects, ; Male; Renal Artery Obstruction, etiology,

The benefit of percutaneous transluminal angioplasty (PTA) of renal transplant artery stenosis for renal hemodynamics is frequently adversely affected by rejection or another complication. As a result, evaluation of the effect of PTA is often difficult. Our study was designed to assess the effect of PTA using a method of integrated value of the glomerular filtration rate (GFR) calculated on the basis of the area under the curve over the follow-up period (AUC0-t). A similar procedure was employed to evaluate mean arterial pressure (MAP). The method was used to assess the outcome in 20 individuals before to PTA, and at 1, 3, 6, 9 and 12 months after angioplasty. A rejection episode was diagnosed in eight cases and glomerulonephritis of the graft in one. Using the evaluation of (AUCCcr)0-12 in relation to the integrated value before PTA (Ccr) x 12, a rise in GFR > 20% was found in 65% of cases. PTA failure was observed in seven individuals developing post-PTA complications. When assessing the integrated value of MAP, PTA was found to be successful (a reduction by at least 10%) in 85% of cases. No significant correlation was demonstrated between the integrated values of GFR and MAP. The results support the assumption that the evaluation of the integrated values of GFR or MAP using AUC0-t allows to characterize, in a simple manner, the degree of renal transplant function or MAP throughout the follow-up period, and to furnish additional information to the values obtained at individual time intervals after the therapeutic procedure.

Keywords: Adult; Angioplasty, Balloon; Area Under Curve; Blood Pressure; Female; Glomerular Filtration Rate; Humans; Kidney Transplantation /adverse effects/; Male; Renal Artery Obstruction /etiology/

Zveřejněno: 1. prosinec 1999  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Stríbrná J, Schück O, Peregrin JH, Krajícková D, Skibová J. [Evaluation of the results of percutaneous transluminal angioplasty of arterial stenosis in the transplanted kidney using area under time curves of the glomerular filtration rate and blood pressure]. Vnitr Lek. 1999;45(12):691-695.
Stáhnout citaci




Vnitřní lékařství

Vážená paní, pane,
upozorňujeme Vás, že webové stránky, na které hodláte vstoupit, nejsou určeny široké veřejnosti, neboť obsahují odborné informace o léčivých přípravcích, včetně reklamních sdělení, vztahující se k léčivým přípravkům. Tyto informace a sdělení jsou určena výhradně odborníkům dle §2a zákona č.40/1995 Sb., tedy osobám oprávněným léčivé přípravky předepisovat nebo vydávat (dále jen odborník).
Vezměte v potaz, že nejste-li odborník, vystavujete se riziku ohrožení svého zdraví, popřípadě i zdraví dalších osob, pokud byste získané informace nesprávně pochopil(a) či interpretoval(a), a to zejména reklamní sdělení, která mohou být součástí těchto stránek, či je využil(a) pro stanovení vlastní diagnózy nebo léčebného postupu, ať už ve vztahu k sobě osobně nebo ve vztahu k dalším osobám.

Prohlašuji:

  1. že jsem se s výše uvedeným poučením seznámil(a),
  2. že jsem odborníkem ve smyslu zákona č.40/1995 Sb. o regulaci reklamy v platném znění a jsem si vědom(a) rizik, kterým by se jiná osoba než odborník vstupem na tyto stránky vystavovala.


Ne

Ano

Pokud vaše prohlášení není pravdivé, upozorňujeme Vás,
že se vystavujete riziku ohrožení svého zdraví, popřípadě i zdraví dalších osob.