Vnitr Lek 2001, 47(10):722-724

[Transcatheter closure of ostium secundum atrial septal defects--initial experience with treatment of adult patients].

M Mates, J Vojácek, J Popelová, J Masura
Oddĕlení invazivní kardiologie Interní kliniky, Fakultní nemocnice v Motole, Praha.

The authors present their initial experience with the use of Amplatzer septal occluder for transcatheter closure of secundum atrial septal defect. For patients where the secundum atrial septal defect type is haemodynamically significant or when paradoxical embolization via the defect is suspected, the catheterization technique is an alternative for cardiosurgical correction of the defect. The morphology of the defect which is the basic criterium for indication of a transcatheter closure is evaluated on transoesophageal echocardiographic examination. The closure takes place under skiascopic and transoesophageal echocardiographic control. The procedure in all three patients (2 women--age 58 and 62 years, 1 man--24 years) treated at our department was without complications. Consistent with formerly published data it may be concluded from our initial experience that when all indication criteria are respected the closure of secundum atrial defect by means of Amplatzer septal occluder is a safe technique and a relatively easy operation with a high rate of primary success.

Keywords: Adult; Balloon Occlusion, instrumentation, ; Cardiac Catheterization; Echocardiography, Transesophageal; Female; Heart Septal Defects, Atrial, diagnostic imaging, ; Humans; Male; Middle Aged; Radiography

Published: October 1, 2001  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Mates M, Vojácek J, Popelová J, Masura J. [Transcatheter closure of ostium secundum atrial septal defects--initial experience with treatment of adult patients]. Vnitr Lek. 2001;47(10):722-724.
Download citation




Vnitřní lékařství

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.