Vnitr Lek 1996, 42(5):303-307

[Comparison of dynamic and isometric loading in echocardiographic examinations in patients with ischemic heart disease].

J Spác, M Blaha, H Nĕmcová, Z Lupínek, I Dvorák
II. interní klinika FNsP u sv. Anny, Brno.

The objective of the work was to compare functional indicators of the left ventricle during isometric (HG) and dynamic (Ergo) echocardiographic load examinations in patients with different grades of ischaemic heart disease. In group A they compared results in 34 patients with affection of three coronary arteries and in group B 15 patients with 1-2 coronary arteries affected. They evaluated the systolic, diastolic blood pressure, heart rate (HR), the index of the diastolic end volume EDV/m2, the index of the systolic end volume ESV/m2, Limacher's index for evaluation of left ventricular motility and the left ventricular ejection fraction (EF) at rest and after both types of loads. The EDV/m2 index increased in group A by 5.2 ml during an isometric load and by 10.4 ml during a dynamic load, in group B it increased by 1.6 and 7.0 ml resp. The values of the ESV/m2 index increased in group A by 8.5 ml during the isometric load and by 14.0 ml during the dynamic load, in group B by 4.1 and 10.8 ml resp. EF values at rest were similar in both groups: group A: 51.4%, B: 51.5%. During the isometric load the EF declined to 45.3% in group A and to 47,1% in group B. During the dynamic load the EF declined to 42% in group A and 42.5 in group B. The dynamic load produces, as compared with the isometric one, a statistically more significant drop of Limacher's index and greater volumetric changes of the left ventricular cavity in the group with 1-2 affected coronary arteries, as compared with the isometric load. In patients with three affected coronary arteries the volumetric changes during an isometric load are comparable with changes after a dynamic load.

Keywords: Coronary Disease, diagnostic imaging, ; Echocardiography; Exercise Test, methods, ; Humans; Stroke Volume; Ventricular Function, Left

Published: May 1, 1996  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Spác J, Blaha M, Nĕmcová H, Lupínek Z, Dvorák I. [Comparison of dynamic and isometric loading in echocardiographic examinations in patients with ischemic heart disease]. Vnitr Lek. 1996;42(5):303-307.
Download citation




Vnitřní lékařství

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.