Vnitr Lek 1994, 40(3):174-178

[Iron stores in patients with chronic kidney failure treated with recombinant human erythropoietin].

J Cermák, E Gregora, J Lachmanová, V Brabec
Ustav hematologie a krevní transfuze, Praha.

Nine patients with anemia of chronic renal failure were treated with recombinant human erythropoietin (rHuEPO) in dose 50-150 IU/kg/week. After 8 weeks the treatment was maintained with 30-50 IU/kg/week for one year. A significant increase of hemoglobin (Hb) level and red blood cell (RBC) count was observed in all patients. Administration of rHUEPO maintained Hb level higher than 100 milligrams and RBC count above 3.0 x 10(12)/l. Iron stores decreased in all patients. Parameters reflecting either the real amount of iron available for erythropoiesis or iron stores in erythroid precursors, i.e. red cell ferritin (eF), free erythrocyte protoporphyrin (FEP) and transferrin saturation (satTRF) were the most reliable tools for diagnosis of iron deficient erythropoiesis. Serum ferritin (sF) was not decreased in most patients, however, sF level was below 50 micrograms/l in all patients at the time of diagnosis of iron deficiency. Iron supplementation in a daily dose allowing absorption of 100mg of elementary iron was sufficient to cover the increased demand for iron in rHuEPO treated patients.

Keywords: Anemia, etiology, ; Erythropoietin, therapeutic use, ; Humans; Iron, metabolism, ; Kidney Failure, Chronic, metabolism, ; Recombinant Proteins, therapeutic use,

Published: March 1, 1994  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Cermák J, Gregora E, Lachmanová J, Brabec V. [Iron stores in patients with chronic kidney failure treated with recombinant human erythropoietin]. Vnitr Lek. 1994;40(3):174-178.
Download citation




Vnitřní lékařství

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.