Vnitr Lek 2001, 47(6):343-347

[Electrophysiologic parameters determining the success of radiofrequency ablation of atrioventricular reentry tachycardia].

P Heinc, M Fiala, J Lukl
I. interní klinika Lékarské fakulty Univerzity Palackého, Olomouc.

The main objective was to assess electrophysiological parameters which may be important for effective radiofrequency ablation of accessory atrioventricular pathways. In a group of 66 patients a total of 490 applications of radiofrequency current were made, incl. 68 which led to successful severing of the accessory pathways. The ablations were successful in 65 patients (98.5%). The potential of the accessory pathways was present in effective ablations in 19 cases of 68 applications (28%), while in ineffective ablations it was present in 13 cases of 421 applications (3%, p < 0.001). Stability of the electrogram was found in all 68 effective ablations (100%), while in ineffective ablations a stable electrogram was found in 248 cases of 323 applications (77%, p < 0.001). In unstable electrograms the ablation was not effective in any of the patients. The V-delta interval was significantly longer in successful ablations (16 +/- 14.2 ms) than in unsuccessful ones (3 +/- 19.4 ms, p < 0.001). The ventriculoatrial interval was in successful ablations significantly shorter (57.5 +/- 22.5 ms) than in unsuccessful ones (74.5 +/- 20.9 ms, p < 0.001). In 90% applications the ventriculoatrial interval was less than 70 ms. Of 10 evaluated parameters the potential of the accessory pathway, stability of the electrogram, V-delta interval (equal or < or = 0) and short ventriculoatrial intervals (equal to or < or = 70 ms) proved important parameters for successful ablation of accessory pathways.

Keywords: Adolescent; Adult; Aged; Catheter Ablation; Electrocardiography; Electrophysiologic Techniques, Cardiac; Female; Heart Conduction System, surgery, ; Humans; Male; Middle Aged; Tachycardia, Atrioventricular Nodal Reentry, physiopathology, ; Treatment Outcome

Published: June 1, 2001  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Heinc P, Fiala M, Lukl J. [Electrophysiologic parameters determining the success of radiofrequency ablation of atrioventricular reentry tachycardia]. Vnitr Lek. 2001;47(6):343-347.
Download citation




Vnitřní lékařství

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.