Vnitr Lek 1997, 43(5):273-278

[A fully implantable port system for venous access. Personal experience with 91 patients].

P Zák, M Tauchman, V Maisnar, K Podzimek, S Mirová, J Voglová, P Dulícek, S Filip, L Chrobák
Oddĕlení klinické hematologie FM, Hradec Králové.

A fully implantable venous port system with a cannula inserted into the central venous system was implanted to 91 patients. The system was used for the administration of different types of intravenous preparations, incl. transfusions of erythrocyte mass and parenteral nutrition. With in the framework of autologous transplantation via the port system haematopoietic progenitor cells from the peripheral blood stream were administered. Part of the introduced systems was used for monitoring of the central venous overpressure and for collecting blood samples. The system was introduced on an average for 289 days, with a median of 245 days, range 82-872 days. During the implantation seven complications developed, in three instances the port was removed prematurely. During treatment 16 complications were observed, which in six instances led to early explantation of the venous port. The number of complications in total amounted to 0.87 per 1000 treatment days. The system was well tolerated by the patients because of its functional effectiveness and minimal cosmetic changes, and because it is not demanding it was also accepted well by the nursing staff.

Keywords: Catheterization, Central Venous, adverse effects, ; Catheters, Indwelling, adverse effects, ; Female; Humans; Male; Time Factors

Published: May 1, 1997  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Zák P, Tauchman M, Maisnar V, Podzimek K, Mirová S, Voglová J, et al.. [A fully implantable port system for venous access. Personal experience with 91 patients]. Vnitr Lek. 1997;43(5):273-278.
Download citation




Vnitřní lékařství

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.