Vnitr Lek 1993, 39(6):536-540

[Atrial-triggered and ventricular-inhibited ventricular VDD pacing with atrial and ventricular single catheter electrodes--the Phymos MPS pacemaker].

P Kamarýt, J Nicovský, P Mach, M Novák, M Richter, J Julínek
I. interní klinika FN U sv. Anny, Brno.

Optimal treatment from the haemodynamic aspect in complete atrioventricular block is dual-chamber DDD pacing. It makes possible atrioventricular sequence and adaptability of the frequency of ventricular pacing to the load under the control of the sinoatrial node. DDD pacing calls, however, for an atrial and ventricular electrode on two leads. Italian authors developed in 1984 a pacemaker (PM) PHYMOS (MEDICO ITALIA) which makes possible atrial triggered ventricular VDD pacing by means of a single pass lead with a tripolar electrode. As the first ones in the post-communist countries the authors implanted to six patients a PM PHYMOS MPS. They confirmed that the advantages of the VDD system, as compared with DDD, are the use of a single pass lead. This makes the implantation quicker, simpler and safer and reduces the time of X-ray irradiation and the incidence of electrodes dislocations. Another advantage is the lower incidence of atrial fibrillation and probably also pacemaker mediated tachycardias. The disadvantages of the VDD system are that atrial stimulation is impossible and that the diameter of the single pass lead is somewhat larger. According to data in the literature and the so far small experience of the authors, when the indication is correct--atrioventricular block grade III or II with intact function of the sinoatrial node--the advantages of VDD pacing with a single pass lead, as compared with DDD pacing, predominate over disadvantages.

Keywords: Aged; Female; Heart Block, therapy, ; Humans; Male; Middle Aged; Pacemaker, Artificial

Published: June 1, 1993  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Kamarýt P, Nicovský J, Mach P, Novák M, Richter M, Julínek J. [Atrial-triggered and ventricular-inhibited ventricular VDD pacing with atrial and ventricular single catheter electrodes--the Phymos MPS pacemaker]. Vnitr Lek. 1993;39(6):536-540.
Download citation




Vnitřní lékařství

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.